Endoscope Electrical Connector Unit, GIF CF PCF 140 Models, Olympus, OEM

Endoscope Electrical Connector Unit, GIF CF PCF 140 Models, Olympus, OEM
Endoscope Electrical Connector Unit, GIF CF PCF 140 Models, Olympus, OEM
Endoscope Electrical Connector Unit, GIF CF PCF 140 Models, Olympus, OEM
Endoscope Electrical Connector Unit, GIF CF PCF 140 Models, Olympus, OEM
Endoscope Electrical Connector Unit, GIF CF PCF 140 Models, Olympus, OEM
Endoscope Electrical Connector Unit, GIF CF PCF 140 Models, Olympus, OEM
Endoscope Electrical Connector Unit, GIF CF PCF 140 Models, Olympus, OEM
Endoscope Electrical Connector Unit, GIF CF PCF 140 Models, Olympus, OEM
Endoscope Electrical Connector Unit, GIF CF PCF 140 Models, Olympus, OEM
Endoscope Electrical Connector Unit, GIF CF PCF 140 Models, Olympus, OEM
Endoscope Electrical Connector Unit, GIF CF PCF 140 Models, Olympus, OEM
Endoscope Electrical Connector Unit, GIF CF PCF 140 Models, Olympus, OEM

Endoscope Electrical Connector Unit, GIF CF PCF 140 Models, Olympus, OEM
The item for sale is an Olympus OEM Electrical Connector Unit. This item includes the following parts. Electrical Connector Light Guide Boot (ELCLGB). Light Guide Tube Distal End Fitting and screws (LDLGTDEF). Rear Cover and screws (mounts onto the electrical connector inside the ELCLGB). With the perfect wire lengths- free of corrosion. Screw: Electrical Hub (SCRELH) (OEM non-magnetic). Pin: Electrical Hub (x2) (PINELH) (yellow pin).

O-Ring: Electrical Hub (ORELH) (rubber gasket to seal hub to connector). Electrical Hub with Burndy Pins (and wire ferrules) (ELHB). Shield Cylinder (SCY) (screws on top of the ELHB).

Shield Disk (SDK) and screws (screws on top of the SCY allowing wires from pins to escape). Holding Plate, Holding Plate Protection Rubber for Shield Disk, and screws (secures wires to SDK). Separator (SEP) (Copper part that separates the hub from interior openings in connector). Holding Plate (x2), Holding Plate Protection Rubber for ELC, and screws (x4) (secures wires to ELC).

Electrical Connector Adaptor Ring (ELCAR) (stainless steel ring that sits on end of connector). Light Guide Rod Unit (LGRU) (crystal rod that the light guide fiber bundle screws onto). Light Guide Cover Glass Unit (LGCGU) (stainless steel sleeve that fastens to ELC and contains LGRU). This electrical connector unit is original. This is perfect for those flooded endoscopes that need an overhaul.

Stock up on these units so you aren't scrambling to find all the parts you need. Or have you ever had to reach into your own endoscope inventory and salvage parts? Now you can avoid the hassle. We can supply your service room, no matter your volume of repairs, for years to come.

This unit is inspected carefully under the microscope to insure it is functional. After years of research we have found that this part can be used on the following model of Olympus endoscopes. GIF-100, GIF-1T100, GIF-2T100, GIF-130, GIF-1T130, GIF-2T130, SIF-100. Please be sure to check out our other listings for the model you are looking for. Our model compatibility lists are ongoing and if you can't find the model you are looking for just send us a message and we will find out for you.

The item listed is used. It has been thoroughly tested and inspected by microscope under 20x magnification by in-house technicians (not authorized by the OEM).

We ensure the item is free of major dents and scratches, and that the overall condition of the item is good. We ensure that the item is fully functional.

This item has been cleaned. More Endoscopy Parts- just visit our store and c heck out our other items. We work hard to provide everyone with original products in exceptional condition and appreciate all responsible buyers. An item that is discovered to be defective upon receipt will be replaced.

Damaged items can be replaced with the same items only. We will not process the return if any of these conditions are not followed. Any product that exhibits physical damage or abuse (whether accidental or due to negligence).

Products that are not eligible for return for any of the above reason(s) will be sent back to you at your cost and expense. The sale of this item may be subject to regulation by the U.

Food and Drug Administration and state and local regulatory agencies. This item will be delivered to buyers prior to any clearly marked expiration or use by date. This item has been opened and used. Regardless of the origin of the equipment, documentation provided or identification appearing upon the equipment, the equipment described and offered here is in no way certified for, recommended for, or offered for any specific use.

The item "Endoscope Electrical Connector Unit, GIF CF PCF 140 Models, Olympus, OEM" is in sale since Thursday, January 23, 2014. This item is in the category "Business & Industrial\Healthcare, Lab & Dental\Handpieces & Instruments\Endoscopes". The seller is "usedendoscopyparts" and is located in Southfield, Michigan. This item can be shipped to United States, Canada, United Kingdom, Denmark, Romania, Slovakia, Bulgaria, Czech republic, Finland, Hungary, Latvia, Lithuania, Malta, Estonia, Australia, Greece, Portugal, Cyprus, Slovenia, Japan, Sweden, South Korea, Indonesia, Thailand, Belgium, France, Hong Kong, Ireland, Netherlands, Poland, Spain, Italy, Germany, Austria, Bahamas, Israel, New Zealand, Philippines, Singapore, Switzerland, Norway, Qatar, Kuwait, Bahrain, Croatia, Malaysia, Saint lucia, Barbados, Bolivia, Egypt, Iceland, Jordan, Cambodia, Cayman islands, Sri lanka, Martinique, Maldives, Nicaragua, Oman, Pakistan, Paraguay.


Endoscope Electrical Connector Unit, GIF CF PCF 140 Models, Olympus, OEM